Breathe in...breathe out

Fresenius Kabi’s syringe pumps are used to gradually administer small amounts of fluid to a patient or for use in chemical and biomedical research.

Injectomat Agilia

  • DPS: The Dynamic Pressure System – DPS – warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated.
  • Anti-bolus system: Reduces significantly bolus after occlusion release (0.2 ml max).
  • Dimensions (H/W/D/) / Weight: 160 x 345 x 135 mm / 2150 g.
  • Battery: NI/MH / Battery capacity minimum: 10 hours at 5 ml/h / Battery replacement: separate compartment – no need for electrical security testing.
  • Power supply: 100 – 240 Vac / 15 VA, external power 9 Vdc by a converter.

 

 

Injectomat Agilia, the new generation of stand alone syringe pumps.

Features:

  • Flow rate range: 0.1- 200 ml/h (depending on the syringe capacity – up to 1200 ml/h).
  • Flow rate accuracy: ± 1% on mechanism ; ± 2 % on syringes.
  • Syringe capacities: 5, 10, 20, 30/35, 50/60 CC.
  • Infusion Modes: ml/h (0.1 ml/h increments).
  • Volume / time: Volume to infuse 0.1 to 99.9 ml / Time: 0 h 01 to 96 h 00.
  • Volume limit: 0.1-999.9 ml (0.1 ml increments).
  • Bolus: Manual bolus: Rate 50-1200 ml/h (50 ml/h increments).
  • Drug library: Initial drug list of 50 agents adjustable with Vigilant®, the IV
  • Medication Safety Solution. Adjustment of the dilution, authorized infusion modes, default infusion modes, flow rate and bolus limits in ml/h.
  • Pressure modes: 2 modes available: variable or 3 pre-set levels – From 100 to 900 mmHg, 50 mmHg increment.

Injectomat MC Agilia

  • Flow rate range: 0.1-1200 ml/h (depending on the syringe capacity).
  • Flow rate accuracy: ± 1% on mechanism ; ± 2 % on syringes.
  • Syringe capacities: 5,10, 20, 30/35, 50/60 CC.
  • Infusion Modes:
  • ml/h.
    Dose rate:
  • Dose units: ng, μg, mg, cal, kcal, U, kU, mmol, mol, Kmol / kg.
  • Time units: 24h / h / min.
  • Dilution setting: X units / ml or X units / Y ml.
  • Volume or dose / time: 0.1-99.9 units ; 00h01- 96h00.
  • Volume limit: 0.1-999.9 ml.
  • Bolus: Manual bolus: Rate: 50 -1200 ml/h; 50 ml/h increment. Programmed bolus (dose or volume/time): 0.1-99.9 units / 0.1-1200 ml/time auto-calculation.
  • Programming modes: No drug names: infusion without any display of the drug names. Drug labeling: infusion with the drug names. Vigilant® Drug’Lib: the secured IV Administration mode with a drug library.
  • Drug labeling: Display of the drug name based on a list of 50 pre-set drug names.
  • Drug libraries: Drug parameters, infusion, bolus and loading dose parameters, authorized infusion modes, infusion mode per default. Inititial drug library of 50 drugs adjustable with Vigilant®, the IV Medication Safety Solution. Up to 120 drugs (depending on comment size) storable in 4 different drug libraries.
  • Pressure modes: 2 modes available: variable or 3 pre-set levels – From 100 to 900
    mmHg, 50 mmHg increment.
  • DPS The Dynamic Pressure System – DPS – warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated.
  • Anti-bolus system: Reduces significantly bolus after occlusion release (0.2 ml max).

Injectomat TIVA Agilia

  • Drug libraries: Drug parameters, infusion, bolus and loading dose parameters, authorized infusion modes, infusion mode per default. Inititial drug library of 50 drugs adjustable with Vigilant®, the IV Medication Safety Solution. Up to 120 drugs (depending on comment size) storable in 4 different drug libraries.
  • Pressure modes: 2 modes available: variable or 3 pre-set levels – From 100 to 900 mmHg, 50 mmHg increment.
  • DPS The Dynamic Pressure System – DPS – warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated.
  • Anti-bolus system: Reduces significantly bolus after occlusion release (0.2 ml max)
  • Flow rate range: 0.1-1200 ml/h (depending on the syringe capacity).
  • Flow rate accuracy: ± 1% on mechanism ; ± 2 % on syringes.
  • Syringe capacities: 5,10, 20, 30/35, 50/60 CC.
  • Infusion modes:
  • ml/h.
  • Dose rate:
  • Dose units: ng, μg, mg, cal, kcal, U, kU, mmol, mol, Kmol / kg.
  • Time units: 24h / h / min.
  • Dilution setting: X units / ml or X units / Y ml.
  • Volume or dose / time: 0.1-99.9 units ; 00h01- 96h00.
  • Volume limit: 0.1-999.9 ml.
  • TCI Functions: Injectomat® TIVA Agilia is an IV anaesthesia system incorporating pharmacokinetics models for Propofol, Remifentanil, Sufentanil in plasma or effect mode.
  • Bolus: Manual bolus: Rate: 50 -1200 ml/h; 50 ml/h increment. Programmed bolus (dose or volume/time): 0.1-99.9 units / 0.1-1200 ml/time auto-calculation.
  • Programming modes: No drug names: infusion without any display of the drug names. Drug labeling: infusion with the drug names. Vigilant® Drug’ Lib: the secured IV Administration mode with a drug library.
  • Drug labeling: Display of the drug name based on a list of 50 pre-set drug names.

Infusia SP7

  • Flow rate range 50 ml syringe: From 0.1 to 1800.0 ml/h
    30 ml syringe: From 0.1 to 1200.0 ml/h
    20ml syringe: From 0.1 to 800.0 ml/h
    10ml syringe: From 0.1 to 400.0 ml/h
    5 ml syringe: From 0.1 to 200.0 ml/h
    Increment: 0.1 ml/h for all syringe types
  • Syringe capacities 5 ml, 10 ml, 20 ml (30 ml), 50 ml (60 ml)
  • Accuracy ±1% device accuracy (without disposable variability), ±3% total accuracy
  • Volume to be infused From 0.0 to 1999.9 ml, 0.1 ml increment
  • Infusion time From 1.0 min to 1999 min, 1 min increment
  • Bolus volume From 1.0 to 100.0 ml, 0.1 ml increment
  • KVO rate 1.0 ml/h or the last delivery rate, whichever is lower

Bolus or Purge rate 50 ml syringe: From 0.1 to 1800.0 ml/h

  • 30 ml syringe: From 0.1 to 1200.0 ml/h
  • 20ml syringe: From 0.1 to 800.0 ml/h
  • 10ml syringe: From 0.1 to 400.0 ml/h
  • 5 ml syringe: From 0.1 to 200.0 ml/h
    Increment: 0.1 ml/h for all syringe types
×